4′ × 6′ Pacific Shoring Lightweight Corrugated Aluminum Shield

$3,860.00

The 4′ × 6′ Pacific Shoring Lightweight Corrugated Aluminum Shoring Shield is a lightweight protective system designed for localized utility excavations, service connections, and underground utility maintenance.

Featuring a 960 PSF shield capacity, this aluminum shield offers manufacturer-tabulated maximum depth ratings of 16 ft (A25), 16 ft (B45), and 16 ft (C60). The light-duty rail weighs 267 lbs (hydraulic) and 250 lbs (static). An optional wheel kit is available for properly configured static systems.

Contact Iron Lot for pricing, availability, and shipping information. Shield selection and use must comply with the manufacturer’s tabulated data and applicable competent-person requirements.

Description

The 4' x 6' Pacific Shoring Lightweight Corrugated Aluminum Shoring Shield is a lightweight, backhoe-liftable protective system designed for utility excavation, underground utility maintenance, and localized repair work. Its 4-foot shield height provides additional vertical coverage compared with the 2-foot-high models, while the compact 6-foot panel length makes it suitable for excavations where longer shields may be unnecessary or difficult to position.

Constructed with horizontal corrugated aluminum sheeting and vertical shoring rails, this shield combines lightweight handling with a manufacturer-rated lateral soil pressure capacity. It is available in hydraulic or pinned static configurations, with an optional wheel kit for approved static-mode applications.

4' x 6' Shield Rating: 960 PSF maximum lateral soil pressure capacity, with manufacturer-tabulated maximum depths of 16 feet in A25, 16 feet in B45, and 16 feet in C60 soil conditions. These ratings apply only when the manufacturer's configuration and installation requirements are met.

Key Features

4' x 6' Shield Dimensions Four-foot shield height and six-foot panel length for localized utility excavation and maintenance projects.
Lightweight Aluminum Construction Horizontal corrugated aluminum sheeting with vertical shoring rails for a lightweight protective system.
960 PSF Shield Capacity Manufacturer-rated maximum lateral soil pressure capacity for the 6-foot panel length.
Hydraulic or Static Mode Available with hydraulic struts or pinned aluminum oversleeves, subject to manufacturer requirements.
Backhoe-Liftable Design Published weights of 267 lbs hydraulic and 250 lbs static for the light-duty rail model.
Optional Wheel Kit Available for properly configured static-mode shield systems, subject to manufacturer limits.

4' x 6' Shield Specifications

Manufacturer Pacific Shoring
Product Type Lightweight Corrugated Aluminum Shoring Shield
Shield Height 4 ft
Panel Length 6 ft
Material Corrugated Aluminum
Shield Capacity 960 PSF
Maximum Depth - A25 16 ft
Maximum Depth - B45 16 ft
Maximum Depth - C60 16 ft
Hydraulic Weight 267 lbs*
Static Weight 250 lbs*
Available Configurations Hydraulic or Static
Optional Accessory Wheel Kit

*Weights are the manufacturer's published values for the 4' x 6' light-duty rail shield configuration. Actual assembled weight may vary with rail selection, strut length, and optional components. Confirm the complete configuration and lifting weight before use.

A25, B45, and C60 represent the manufacturer's tabulated soil pressure assumptions. C60 is not an OSHA Appendix A soil classification. The referenced selection table does not provide a C80 depth rating for this shield.

Ideal Applications

The 4' x 6' lightweight corrugated aluminum shield is a practical option for localized utility excavation projects where a four-foot shield height is needed, but the excavation does not require the longer panel lengths available in the series.

Its relatively compact dimensions may be advantageous for utility crews working in streets, easements, and congested jobsites where equipment access and shield positioning are important.

  • Localized water and sewer utility repairs
  • Water service connections, utility tie-ins, and spot repairs
  • Underground electrical, gas, and telecommunications utility exposure
  • Utility inspection, maintenance, and repair work
  • Short excavation sections where a compact shield footprint is beneficial
  • Appropriate static-mode utility work using the optional wheel kit

Suitability depends on the dimensions of the pipe, utility component, or structure being installed or repaired, as well as excavation geometry, soil conditions, and the manufacturer's tabulated data. A competent person must verify that the selected shield configuration is appropriate for the project.

Hydraulic and Static Configurations

Hydraulic Configuration

Uses Pacific Shoring 2-inch hydraulic struts with aluminum tube oversleeves.

The manufacturer specifies a minimum hydraulic pressure of 750 psi using shoring fluid. Installation, strut spacing, and any stacking arrangements must comply with the manufacturer's tabulated data.

Static Configuration

Uses pinned aluminum oversleeves without hydraulic pressurization.

Static shields may be stacked up to three deep when permitted by the manufacturer's depth limits and approved stacking bracket requirements.

The optional wheel kit requires static-mode operation.

Optional Wheel Kit

Pacific Shoring offers an optional wheel kit for properly configured static-mode corrugated aluminum shield systems. The kit can assist with repositioning the shield along an excavation when the project conditions and approved configuration permit its use.

Wheel-kit selection must follow the manufacturer's requirements for trench width, receiver length, crossbar material, and the number of attached shields.

  • Wheel-kit use is limited to static-mode shields.
  • Crossbars must be selected according to the manufacturer's wheel-kit tables and pinned to the wheel kit.
  • Shield connections must be secured at all four corners.
  • Stacked shields must be pinned together at all four corners.
  • Maximum combined shield weight attached to the wheel kit: 1,380 lbs.

Trench Width and End Sheeting

The Pacific Shoring lightweight corrugated shield system has manufacturer-stated allowable trench widths of 2 to 10 feet without end sheeting and 2 to 7 feet with end sheeting, subject to the specific configuration and tabulated data.

Optional end sheeting uses telescoping brackets and requires either a hydraulic configuration with standard 2-inch cylinders pressurized to 1,000 psi, or a static four-sided configuration with sheeting on both ends.

End sheeting is not included as a standard feature of the 4' x 6' shield. Verify all component, material, and installation requirements before use.

Manufacturer Tabulated Data and Safety

The manufacturer's tabulated data governs the allowable use of this shield. The data references OSHA 29 CFR 1926 Subpart P and includes requirements for soil classification, trench width, allowable depth, surcharge loads, shield configuration, stacking, and optional accessories.

Safety and Selection Notice: A competent person must classify the soil and verify all applicable manufacturer requirements before installing or using the shield. Maximum depth ratings do not eliminate the need to evaluate actual excavation conditions. Installation, removal, and worker entry must comply with the manufacturer's instructions and applicable OSHA requirements.

Request Pricing and Availability

Contact Iron Lot for pricing and availability on the 4' x 6' Pacific Shoring Lightweight Corrugated Aluminum Shoring Shield.

Let us know whether you need a hydraulic or static configuration, your required trench width, quantity, optional accessories, and delivery location.

Request a Quote

Product Specifications

Weight 265 lbs
Dimensions 72 × 48 × 36 in
Model

Lightweight Corrugated Aluminum Shield

Trench Box Size

4×6

Wall Thickness

2 Inch Wall

Material

Aluminum

System Type

Trench Box

Shield Height

4 ft

Shield Length

6 ft

Manufacturer

Pacific Shoring

Reviews