8′ x 8′ Kundel Basic 3 Steel Trench Box

$8,261.55

Standard Two Sided Kit Includes:

(2) 8×8 Steel Panels

(4) 36″-60″ Spreaders

Plus Required Hardware for Assembly

*Additional Spreader Options and Configurations Available

This Product Ships from Ohio – Lead Times Vary

The Kundel Basic 3 is one of several steel trench boxes  available from Iron Lot for utility, excavation, and municipal applications.

Available on backorder

SKU: B3-8x8-K-KI Categories: , Brand:

Description

8′ x 8′ Kundel Basic 3 Steel Trench Box

The Kundel Basic 3 8′ x 8′ steel trench box is a durable utility shield designed for municipalities, plumbing contractors, industrial maintenance departments, and underground utility crews using properly rated compact excavators, small excavators, or rubber-tired backhoes.

This model combines an 8-foot sidewall height with an 8-foot overall length. It provides substantial vertical panel coverage and a practical working area for utility spot repairs, service taps, service connections, minor mainline work, and localized infrastructure maintenance.

The 7-foot opening between spreaders may provide room for compatible pipe, valves, fittings, utility connections, tools, and crew movement. Compared with the shorter 8′ x 6′ Basic 3 model, this box offers additional longitudinal working space while remaining easier to position than a longer 10- or 12-foot trench shield.

The Basic 3 uses 3-inch double-wall, solid-welded steel sidewalls built for demanding field conditions. This model has a listed weight of approximately 1,912 lbs and includes a knife-edge bottom to assist with manufacturer-approved positioning in compatible excavation conditions.

Each Basic 3 trench box requires four compatible spreaders. Spreaders are sold separately and must be selected according to the required inside working width, excavation geometry, utility-component clearances, lifting equipment, and Kundel’s current tabulated data.

Key Benefits & Crew Efficiency

  • 8-Foot Sidewall Height: Provides substantial vertical panel coverage for compatible utility repair and maintenance excavations.
  • 8-Foot Overall Length: Offers a practical work area without requiring the excavation and positioning space of a longer 10- or 12-foot shield.
  • 7 Feet Between Spreaders: Provides open longitudinal space for compatible pipe, valves, fittings, tools, and service connections.
  • Knife-Edge Bottom: Assists with manufacturer-approved placement and positioning in compatible soil conditions.
  • Approximately 1,912 lbs: Intended for handling with properly rated excavation and lifting equipment.
  • Steel Alternative to Aluminum: Provides durable welded-steel construction in a product line designed for smaller excavation equipment.
  • Double-Wall Construction: Three-inch steel sidewalls are built for repeated use on municipal, plumbing, utility, and industrial maintenance projects.
  • Solid-Welded Steel Design: Provides a durable structural assembly for regular field use.
  • Cast Steel Spreader Collars: Provide durable connection points for compatible Kundel Basic 3 spreaders.
  • Forged Spreader Pins: Secure compatible spreaders within the box’s collar system.
  • Integrated Tamping Blocks: Provide reinforced contact areas for manufacturer-approved positioning procedures.
  • Integrated Lifting Lugs: Provide designated lifting points for properly rated rigging and equipment.
  • Standalone or Base-Box Use: May be used independently or as the lower section in an approved stacked Basic 3 configuration.
  • Tandem Capability: Compatible boxes may be connected in tandem when the complete arrangement is permitted by Kundel’s tabulated data.

Product Specifications

Product Code B3-8x8-K-KI
Manufacturer Kundel
Product Line Basic 3
Product Type Steel Trench Box with Knife Edge
Dimensions 8′ High x 8′ Long
Overall Height 96 Inches
Overall Length 96 Inches
Length Between Spreaders 84 Inches / 7 Feet
Pipe Clearance 27 Inches
Sidewall Thickness 3 Inches
Construction Double-Wall, Solid-Welded Steel
Bottom Configuration Knife Edge
Listed Weight Approximately 1,912 lbs
Required Spreaders Four Compatible Spreaders, Sold Separately
Maximum Depth Rating – Type A Soil 65 ft
Maximum Depth Rating – Type B Soil 37 ft
Maximum Depth Rating – Type C Soil 28 ft

Pricing & Logistics

Listed Price: $8,261.55

The listed price is for the Kundel Basic 3 8′ x 8′ trench box. Four compatible spreaders are required to assemble a complete box and are sold separately.

Contact Iron Lot to confirm current pricing, availability, compatible spreader lengths, stacking components, tandem connectors, optional accessories, applicable taxes, and freight charges.

Required Spreaders

Each Basic 3 trench box requires four compatible spreaders. The correct spreader length depends on the desired inside working width, excavation geometry, pipe or utility-component dimensions, equipment clearance, and the limitations established in Kundel’s current tabulated data.

Spreaders should not be assumed to be included in the listed trench-box price. Confirm the required spreader size, quantity, forged spreader pins, and complete assembled configuration before ordering.

Optional Accessories

Available Basic 3 accessories may include:

  • Compatible spreaders
  • 12″ x 12″ utility cutout
  • Stacking rings
  • Tandem connectors
  • Replacement forged spreader pins
  • Compatible rigging and handling equipment

Optional accessories must be selected for this specific box and intended application. Confirm compatibility, pricing, and availability when requesting a quote.

Freight and Delivery Coordination

The trench box has a listed weight of approximately 1,912 lbs before adding spreaders, stacking rings, tandem connectors, rigging, or other accessories. The final assembled and shipping weight depends on the complete ordered configuration.

Transportation and unloading plans should account for the 96-inch panel height, 8-foot panel length, component securement, lifting capacity, rigging arrangement, unloading equipment, and available assembly space.

Iron Lot can coordinate delivery to a contractor yard, municipal facility, equipment location, or jobsite.

Target Applications

The Kundel Basic 3 8′ x 8′ is primarily suited to localized utility and maintenance excavations where crews need an 8-foot shield height and a practical working length.

Potential applications may include:

  • Water and sewer utility spot repairs
  • Water-main and sewer-main taps
  • Service-line connections
  • Utility tie-ins, tees, crosses, and localized fittings
  • Valve, meter, and curb-stop access
  • Localized utility exposure and maintenance
  • Minor mainline repair work
  • Gas-service repairs and connections
  • Electrical and telecommunications service work
  • Plumbing repair excavations
  • Industrial maintenance projects
  • Emergency municipal utility repairs
  • Work in streets, easements, and congested jobsites

The 8-foot overall length provides more working room than the 8′ x 6′ Basic 3 model. This additional space may be useful for compatible pipe, valves, fittings, service connections, tools, rigging, and crew movement.

Compared with a 10- or 12-foot box, this model requires less longitudinal excavation and positioning space. That may make it easier to use around pavement limits, existing utilities, nearby structures, traffic-control restrictions, landscaping, and other jobsite obstacles.

This model should not be selected solely because its 8-foot sidewall height corresponds with the anticipated excavation depth. Suitability depends on the actual dimensions and locations of the pipe, fitting, valve, structure, utility component, tools, equipment, and required crew workspace.

Customers should verify that the 84-inch length between spreaders and 27-inch pipe clearance provide adequate room for the intended work.

Standalone and Base-Box Configurations

The Basic 3 8′ x 8′ may be used as a standalone trench box where its height, length, inside width, working clearances, depth ratings, and complete assembled configuration are appropriate for the excavation.

Because it is an 8-foot-high box, it may also serve as the lower or base section in an approved stacked Basic 3 configuration. A compatible 4-foot- or 6-foot-high Basic 3 extension section may be installed above the base box when the complete arrangement is permitted by Kundel’s current tabulated data.

The base box, upper section, spreaders, stacking rings, connection points, structural capacities, panel lengths, and complete stacked system must all be compatible.

Do not stack boxes solely because their exterior dimensions appear similar. Confirm the approved connection method, spreader compatibility, complete assembled weight, lifting requirements, and tabulated limitations before use.

Tandem Configurations

Compatible Basic 3 trench boxes may be connected in tandem to create a longer shielded work area when the arrangement is supported by Kundel’s current tabulated data.

Tandem configurations require approved connectors and a complete evaluation of the boxes, selected spreaders, connection locations, excavation geometry, utility dimensions, lifting plan, and manufacturer requirements.

Do not use improvised connections or assume that placing two trench boxes next to each other creates an approved tandem configuration.

Critical Selection & Safety Factors

Is the Kundel Basic 3 8′ x 8′ Right for Your Excavation?

The exterior height and length of a trench box do not by themselves determine whether it is suitable for a project.

The selection process should consider:

  • Whether the box will be used independently, as a stacked base box, or in tandem
  • Compatibility with any selected Basic 3 extension section
  • Excavation depth, width, length, and geometry
  • Available longitudinal working and placement space
  • Soil classification
  • Surcharge loads
  • Groundwater and changing soil conditions
  • Traffic, structures, spoil piles, and equipment near the excavation
  • Pipe, fitting, valve, structure, and utility-component dimensions
  • The 84-inch opening between spreaders
  • Required longitudinal, vertical, and lateral working clearances
  • Selected spreader length and resulting inside width
  • Access and egress requirements
  • Lifting, placement, and removal equipment
  • Stacking rings, tandem connectors, and optional cutouts
  • The complete protective-system configuration

The project’s Competent Person must inspect the excavation, classify the soil, evaluate changing conditions and adjacent hazards, and verify that the selected trench-protection system is appropriate for the excavation and used correctly.

Depth Ratings & Tabulated Data

The listed maximum soil depth ratings for the Basic 3 8′ x 8′ are:

  • Type A soil: 65 feet
  • Type B soil: 37 feet
  • Type C soil: 28 feet

These ratings must be interpreted through Kundel’s current tabulated data. They do not mean that an 8-foot-high trench box automatically provides a shielded work area at the listed excavation depths.

The allowable depth may depend on the selected spreader width, complete system configuration, soil conditions, surcharge loads, groundwater, excavation geometry, box placement, stacking arrangement, and other jobsite factors.

The listed depth rating is not the same as the available shielded work-area height. Placement of the trench box relative to the excavation bottom and the top of the excavation must comply with Kundel’s instructions, current tabulated data, and applicable requirements.

Excavations exceeding 20 feet in depth generally require a protective system designed or approved under the applicable engineering requirements. Do not rely on product-page ratings as a substitute for Kundel’s current tabulated data or a project-specific engineered design when one is required.

Assembly, Lifting & Inspection

The Basic 3 trench box must be assembled with four compatible spreaders and the required forged spreader pins before use. Stacked or tandem configurations also require all approved connecting components.

The complete box should be lifted, lowered, repositioned, and removed using the designated lifting lugs, properly rated rigging, and equipment with sufficient capacity for the complete assembled weight.

The 96-inch panel height and 8-foot panel length require careful control during assembly, lifting, positioning, and removal. Tamping blocks provide reinforced contact areas, while the knife-edge bottom assists with manufacturer-approved positioning in compatible soil conditions.

Do not strike unapproved areas of the sidewalls, spreader collars, lifting lugs, knife edge, or other structural components.

Before each use, inspect:

  • Double-wall steel sidewalls
  • Knife-edge sections
  • Cast steel spreader collars
  • Spreaders and forged spreader pins
  • Tamping blocks
  • Lifting lugs
  • Stacking rings and connection points
  • Tandem connectors
  • Welds and structural areas
  • Optional utility cutouts
  • All components for cracks, bends, distortion, damage, or excessive wear

Damaged or questionable components should be removed from service until they have been evaluated according to the manufacturer’s requirements.

Why Choose the Kundel Basic 3 8′ x 8′?

The Basic 3 8′ x 8′ combines substantial sidewall height, a practical working length, and durable welded-steel construction. It is designed for crews that need more working room than the 8′ x 6′ configuration provides without moving to a longer 10- or 12-foot shield.

The 7-foot opening between spreaders may provide useful room for compatible pipe, valves, fittings, utility connections, tools, rigging, and crew movement. The 8-foot overall length can also remain manageable for streets, easements, industrial facilities, and other jobsites where placement space is limited.

The box may be used independently or serve as the base section in an approved stacked Basic 3 configuration when additional vertical panel coverage is required.

The double-wall steel sidewalls, cast steel spreader collars, forged pins, tamping blocks, lifting lugs, and knife-edge bottom provide a durable, field-ready system for municipal, plumbing, industrial maintenance, and underground utility crews.

Final selection must be based on the actual excavation, intended application, pipe or utility-component dimensions, selected spreaders, complete standalone or stacked configuration, Kundel’s current tabulated data, and the requirements established by the project’s Competent Person.

Request Pricing and Availability

Iron Lot supplies trench boxes and trench safety equipment to contractors throughout the United States.

Contact us for:

  • Current product availability
  • Spreader selection and pricing
  • Multiple-unit quotations
  • Freight quote and delivery coordination
  • Alternative aluminum trench box options
  • Steel versus aluminum trench box comparisons
  • Equipment financing information

This Product Ships from Ohio

Payment Options:

We accept company check, wire transfer, ACH, and credit card payments. We also offer financing through Ascentium Capital.

Financing: Ascentium Capital offers fast and flexible financing. With their quick and convenient way to purchase equipment, working with Ascentium Capital helps you acquire the funds you need for your equipment purchase. With financing and leasing of up to $2,000,000, Ascentium Capital works with you to make the application process simple and at no obligation.

To learn more about Ascentium Capital and how it can assist you, click image below:

Ascentium Capital Equipment Financing

Call Iron Lot at 336-516-8011 or request a quote online for current pricing, availability, and freight information.

Not sure which trench box is right for your project? Compare additional trench boxes for sale, including steel, aluminum, and manhole box options.

Product Specifications

Weight 2095 lbs
Dimensions 96 × 48 × 36 in
Model

Basic 3

Trench Box Size

8×8

Wall Thickness

3 Inch Wall

Material

Steel

System Type

Trench Box

Manufacturer

Kundel

Shield Height

8 ft

Shield Length